Universal­Extractor E-800

Powerful and perfect for multitasking

The UniversalExtractor E-800 is powerful and perfect for demanding extraction tasks. Distinct extraction positions enable individual process control and simultaneous operation of 6 different extraction methods with high speed and reproducibility.

  • Application:Extraction of food, environmental samples, polymers or natural products
  • Extraction methods:Soxhlet, Soxhlet warm, Hot extraction, Continuous flow, Twisselmann
  • Solvents:water, organic solvent with bp < 150°C
UniversalExtractor E-800

Multitasking

Six distinct extraction positions enable individual process control and simultaneous operation of different extraction methods, so you can execute multiple work packages in parallel. With the powerful and perfect for multitasking UniversalExtractor E-800, you can develop methods faster and boost your sample throughput.

Multitasking

Analyte protection sensor

Obtain the highest analyte recoveries thanks to a unique analyte protection feature, which ensures that always a minimal level of solvent is found in the beaker. The UniversalExtractor E-800 prevents the deterioration and degradation of heat-sensitive analytes during all process steps and ensures safe and reproducible concentration of the extract.

Analyte protection sensor

Fully inert conditions and maximized safety for the analyte

All components in the UniversalExtractor E-800 that are in contact with the sample and the solvents are made of completely inert materials. With our system, you eliminate the risks of sample contamination and any memory effects from leaching materials. You can select the inert gas supply at all process steps (extraction, rinsing, drying) to protect the analyte against oxidation. Inert gas is automatically switched on if the analyte protection sensor is triggered

Fully inert conditions and maximized safety for the analyte

Features

  • The analyte protecion sensor monitors the solvent level in the beaker and prevents the beakers from running dry, so your process is safer and your heat-sensitive analytes are well-protected.

    Analyte protection sensor
  • The large condenser captures vapours efficiently and ensures highest solvent recovery (> 90 %), even with volatile solvents. Any emission of vapours is eliminated and allows for operation outside of the fume hood. 

    High performance condensers
  • The entire extraction process is visible. You can easily access, disassemble, clean the glass assemblies, which can be decontaminated in the oven (baking out at + 450 °C).

    Full visibility
  • You can readily achieve the detection limit of the analyte by using the LSV glass assembly with the larger extraction chamber and beaker designed for higher sample quantities. The LSV glass parts are 60% larger than the standard version.

    Optimal sample size

Compare the UniversalExtractor E-800

  • UniversalExtractor E-800 HE

    • Extraction method:Hot extraction (=Randall=Submersion)
    • Chamber heating elements:no
    • Inert gas supply:no
    • Solvents:Organic solvents, Water
    • Boiling point solvents:< 150 °C
    • Glass sample tube:Standard (65 mL)
    • Thimble sizes:33 x 94 mm, 25 x 100 mm
  • UniversalExtractor E-800 HE

    • Extraction method:Hot extraction (=Randall=Submersion)
    • Chamber heating elements:no
    • Inert gas supply:no
    • Solvents:Organic solvents, Water
    • Boiling point solvents:< 150 °C
    • Glass sample tube:Standard (65 mL)
    • Thimble sizes:33 x 94 mm, 25 x 100 mm
  • UniversalExtractor E-800 Standard

    • Extraction method:Soxhlet, Continous flow
    • Chamber heating elements:no
    • Inert gas supply:no
    • Solvents:Organic solvents, Water
    • Boiling point solvents:< 150°C
    • Glass sample tube:Standard, long (130 mL)
    • Thimble sizes:25 x 150 mm, 33 x 150 mm
  • UniversalExtractor E-800 Standard

    • Extraction method:Soxhlet, Continous flow
    • Chamber heating elements:no
    • Inert gas supply:no
    • Solvents:Organic solvents, Water
    • Boiling point solvents:< 150°C
    • Glass sample tube:Standard, long (130 mL)
    • Thimble sizes:25 x 150 mm, 33 x 150 mm
  • UniversalExtractor E-800 Pro

    • Extraction method:Soxhlet, Soxhlet warm, Hot extraction, Continous flow, Twisselmann
    • Chamber heating elements:yes
    • Inert gas supply:no
    • Solvents:Organic solvents, Water
    • Boiling point solvents:< 150°C
    • Glass sample tube:Standard, long (130 mL)
    • Thimble sizes:25 x 150 mm, 33 x 150 mm
  • UniversalExtractor E-800 Pro

    • Extraction method:Soxhlet, Soxhlet warm, Hot extraction, Continous flow, Twisselmann
    • Chamber heating elements:yes
    • Inert gas supply:no
    • Solvents:Organic solvents, Water
    • Boiling point solvents:< 150°C
    • Glass sample tube:Standard, long (130 mL)
    • Thimble sizes:25 x 150 mm, 33 x 150 mm
  • UniversalExtractor E-800 Pro Inert

    • Extraction method:Soxhlet, Soxhlet warm, Hot extraction, Continous flow, Twisselmann
    • Chamber heating elements:yes
    • Inert gas supply:yes
    • Solvents:Organic solvents, Water
    • Boiling point solvents:< 150°C
    • Glass sample tube:Standard, long (130 mL)
    • Thimble sizes:25 x 150 mm, 33 x 150 mm
  • UniversalExtractor E-800 Pro Inert

    • Extraction method:Soxhlet, Soxhlet warm, Hot extraction, Continous flow, Twisselmann
    • Chamber heating elements:yes
    • Inert gas supply:yes
    • Solvents:Organic solvents, Water
    • Boiling point solvents:< 150°C
    • Glass sample tube:Standard, long (130 mL)
    • Thimble sizes:25 x 150 mm, 33 x 150 mm
  • UniversalExtractor E-800 Pro LSV

    • Extraction method:Soxhlet, Soxhlet warm, Hot extraction, Continous flow, Twisselmann
    • Chamber heating elements:yes
    • Inert gas supply:no
    • Solvents:Organic solvents, Water
    • Boiling point solvents:< 150°C
    • Glass sample tube:LSV, long (220 mL)
    • Thimble sizes:33 x 150 mm, 43 x 150 mm
  • UniversalExtractor E-800 Pro LSV

    • Extraction method:Soxhlet, Soxhlet warm, Hot extraction, Continous flow, Twisselmann
    • Chamber heating elements:yes
    • Inert gas supply:no
    • Solvents:Organic solvents, Water
    • Boiling point solvents:< 150°C
    • Glass sample tube:LSV, long (220 mL)
    • Thimble sizes:33 x 150 mm, 43 x 150 mm
"The E-800 is the most versatile extraction unit, capable of handling all sample type as it supports multiple types of extraction"Muhammad Omer, Sr Agriculturist & Food Chemist - Intertek, Pakistan

Downloads

Discover more documents

Applications

From classical fat to residue and contaminant analysis

BUCHI offers dedicated extraction solutions for fat determination, as well as for residue and contaminant analysis in various matrices. We cover the entire range of automated extraction methods. Our solutions allow for perfect workflow integration, thus minimizing manual steps.
  • Environmental Analysis

    Extraction as sample preparation prior to analysis of persistent organic pollutants (POPs), contaminants and residues from soil, sediments, air filters and waste samples.

    Environmental Analysis
  • Chemicals

    Extraction of materials and chemicals for QC as well as for R&D. Determination of total extractables, contaminants and additives.

    Chemicals
  • Pharmaceutical

    Extraction as sample preparation for the research of active compounds in plants (for medical or cosmetic use).

    Pharmaceutical