Interface I-80 / I-180

Affordable vacuum regulation

The Interface I-80 / I-180 is the optimal solution for affordable and efficient vacuum regulation. For the user’s convenience, the Interface I-80 / I-180 can be mounted on top of the Rotavapor® R-80 to have one central control unit or be attached to the Vacuum Pump V-80 / V-180 or a lab stand.

  • Compatibility:Vacuum Pump V-80/V-180
  • Timer function:To turn off vacuum control after a pre-set time
  • Manual vacuum control:Pressure settings, pump speed and aeration (I-180 only) are all managed with one control knob
Interface I-80 / I-180

Convenient and intuitive

The Interface I-180 provides you with user-friendly handling thanks to the self-explanatory display. Benefit from precise vacuum control from the most convenient location, made possible by versatile mounting options. An external valve unit allows vacuum control in combination with a pre-installed house vacuum solution.

Cost-efficient option

The Interface I-80 is a suitable option for those with basic needs. The Interface I-80 is used for manual vacuum control. Thanks to the central navigation control of the Interface I-80, you can conveniently control the pump speed, and a needle valve allows fine-tuning of the final pressure.

Navigation control

The Interface I-180 is very easy to use, and it automatically controls the vacuum and has one central navigation control with which all major parameters can be set. For more flexibility, the vacuum can be controlled by targeting a set pressure or with the continuous mode.

Features

  • The Interface I-180 is provided with an automatic method for testing the airtightness of the Rotavapor®.

  • You can manage pressure settings and aeration on the I-180 via a central turning wheel and button.

  • Automatic aeration with the Interface I-180 when the pressure rises above 1300 mbar.

  • The reliable vacuum regulation of the Interface I-180 adjusts and keeps the pressure stable within the hysteresis.

  • The Interface I-80 / I-180 can flexibly be mounted onto the Rotavapor® R-80, the Vacuum pump V-180, and a lab-stand.

Compare the Interface I-80 / I-180

  • Interface I-80

    I-80_comparison.tiff
    • Display:Dark segment display, 3.0 in
    • Installation:-
    • Method programming:No
    • Solvent library:No
    • Dynamic distillation:-
    • Eco mode:-
    • Foam sensor possibility:No
  • Interface I-180

    I-180_comparison.tiff
    • Display:Dark segment display, 3.0 in
    • Installation:-
    • Method programming:No
    • Solvent library:No
    • Dynamic distillation:-
    • Eco mode:-
    • Foam sensor possibility:No
  • Interface I-300 Pro

    11I300P00.jpg
    • Display:LCD, 7.0 in
    • Installation:On Rotavapor R-300, Vacuum pump V-300 or house vacuum
    • Method programming:Yes
    • Solvent library:Yes
    • Dynamic distillation:Yes
    • Eco mode:Yes
    • Foam sensor possibility:Yes
  • Interface I-300

    11I300S00.jpg
    • Display:LCD, 4.3 in
    • Installation:On Rotavapor R-300, Vacuum pump V-300 or house vacuum
    • Method programming:No
    • Solvent library:Yes
    • Dynamic distillation:Yes
    • Eco mode:Yes
    • Foam sensor possibility:Yes