Dist Line
Providing highest flexibility for every application
The Dist Line is extremely versatile and is designed for a broad range of analytes while offering the highest operational safety. The instruments perfectly fit your individual needs and enable the highest performance in the most flexible way.
Features
For more convenience and easier sample handling, we offer configurations with sample tube and receiver waste aspiration. This saves time and allows for smooth operation of the instrument.
Thanks to the AutoDist function, measurements are unaffected by temperature differences within the device. This function recognizes the start of the condensation process and adjusts the distillation start time automatically in the individual measurement. This is achieved with a built-in temperature sensor within the condensate vessel and leads to more reproducible results.
Automated titration is key to achieving the highest performance possible in Kjeldahl protein determination. Titration dosage, as well as endpoint recognition via suitable electrodes, is carried out automatically. This allows for minimum user interaction and high throughput at the same time.
The cooling water control automatically saves water by intelligent flow limitation. Once steam distillation starts, water begins to flow through the condenser and the distillate is collected. Before and after distillation, the device automatically closes the cooling water valve. This feature saves approximately 20 % of water during determinations and eliminates concerns regarding the water supply.
The OnLevel sensor is available for all configurations where no titration vessel is mounted. The sensor stops the distillation automatically after a defined condensate volume is reached. The sensor can be easily set and adjusted manually via a magnetic backplate. Obtain reproducible condensate volumes independent of the system lifetime.
With our versatile components, you can easily upgrade and automate your system for highest convenience. All parts can be chosen separately and can be combined one after another. The modular design allows you to achieve an optimal combination of features to suit your individual needs. In this way, you receive the optimum combination of features and peripherals according to your needs.
The intuitive touch screen provides fast feedback and enables easy process handling
Glass and plastic splash protectors are available. Glass splash protectors enable you to monitor the process to support method development and optimization. Plastic splash protectors are more robust and durable. Depending on the application, different splash protector variants enable the best performance
The Kjel Line instruments reduce user exposure to a minimum thanks to innovative sensor technology. Safety sensors monitor cooling water flow, steam generator pressure and if the sample tube is put correctly in place. Tank level sensors detect water, waste and reagent levels. The safety shields are fully transparent and equipped with secure control sensors. If the safety shields are opened during operation, the process is stopped automatically. The steam power is adjustable (10 - 100 %) and steam ramps are programmable to handle foaming samples.
In laboratories, deviations of the supply voltage are possible within a range of up to 10 % of the original value. This can potentially affect the steam power output. In order to avoid these deviations, a voltage stabilizer is integrated to maintain the required supply voltage. This enhances measurement accuracy and ensures highest reproducibility for every result.
Compare the Dist Line
Related Parts & Accessories
Downloads
- Operation Manual K-365 Dist Line en(pdf)
- Technical Data Sheet K-365 Dist Line(pdf)
- Product Brochure Dist Line en(pdf)
- Solution Brochure Digestion and Distillation en(pdf)
- Solution Brochure Environmental Analysis en(pdf)
Related Instruments
Related Courses & Trainings
Applications
Thanks to a wide variety of ready-made applications
Feed / Agricultural Products
Mixed and finished feed (ruminant, swine, poultry), ingredients such as oil seed meals, cereals, hulls & bran Protein, Total Kjeldahl Nitrogen (TKN), Non-Protein Nitrogen (NPN) Protein: AOAC 2001.11 / 920.87 / 930.25 / 945.39 / 950.09 / 979.09 / 981.10 / ISO 1656 / 3188 / 20483
Chemicals / Fertilizers
Basic chemicals, petro-chemicals and specialty chemicals, fertilizers, cosmetics, lubricant oils Ammonia, nitrate/nitrite, cyanide (CN-), formaldehyde, Total Kjeldahl Nitrogen (TKN) Nitrate/nitrite: DIN 38409 Part 28 / DIN CEN/TS 15476 Cyanide: EPA 9010 C/335.2 Nitrogen: AOAC 955.04 / 981.1 / DIN EN 15750
Environmental Samples / Testing
Water samples, soil samples, waste water, fly ash Ammonia, Total Kjeldahl Nitrogen (TKN), phenol, formaldehyde, nitrate/ nitrite Formaldehyde, Phenol: DIN 38409-H Nitrate/nitrite: DIN 38409 Part 28 / DIN CEN/TS 15476 Nitrogen: DIN EN 13342 / 38409 Part 28
Beverages
Beer, wine, fruit juice, dairy products, water Alcohol, sulfite and sulfur dioxide (SO2), volatile acids, vicinal diketones (VDKs), essential oils, protein, Total Kjeldahl Nitrogen (TKN) Alcohol: OIV MA-AS312-01A:R2016 SO2 Monier-Williams: AOAC 990.28 / OIV-MA-AS323-04A/B Protein: AOAC 920.53 / 991.20 / 981.10 / ISO 8968-3
Food
FoodCereals, dairy products, meat, pastry, seafood, ready meals, plant-based food Protein, Total Kjeldahl Nitrogen (TKN), Non-Protein Nitrogen (NPN), Total Volatile Basic Nitrogen (TVBN), casein, sulfite and sulfur dioxide (SO2), hydroxyproline Protein: AOAC 2001.11 / 920.87 / 925.31 / 928.08 / 930.25 / 950.48 / 979.09 / 981.10 / 991.20 / ISO 937 / 3188 / 8968-3 SO2 Monier-Williams: AOAC 892.02 / European Regulation 2003/89/EC